| E0 Three-digit 7-segment display shows EE0 | Lockout after three failed ignition attempts | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π§ Check first |
| E1 Three-digit 7-segment display shows EE1 | Low-stage pressure switch closed at start of heating | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E2 Three-digit 7-segment display shows EE2 | Low-stage pressure switch circuit open | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E3 Three-digit 7-segment display shows EE3 | Primary limit circuit open (furnace overheating) | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π§ Check first |
| E4 Three-digit 7-segment display shows EE4 | Flame sensed with no call for heat | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E5 Three-digit 7-segment display shows EE5 | Open fuse on the control | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E6 Three-digit 7-segment display shows EE6 | Weak flame sense signal | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E7 Three-digit 7-segment display shows EE7 | Problem with igniter circuit | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E8 Three-digit 7-segment display shows EE8 | High-stage pressure switch closed at start of heating | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E9 Three-digit 7-segment display shows EE9 | High-stage pressure switch circuit open | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| EA Three-digit 7-segment display shows EEA | Reversed 115 volt polarity | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| Eb Three-digit 7-segment display shows EEb | External gas valve error (valve not energized) | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| EC Three-digit 7-segment display shows EEC | Internal gas valve error (valve energized when it should not be) | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| Ed Three-digit 7-segment display shows EEd | Auxiliary limit switch open (blower compartment) | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π§ Check first |
| EF Three-digit 7-segment display shows EEF | Condensate (AUX) switch open | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π§ Check first |
| E10 Three-digit 7-segment display shows E10 | Grounding fault | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| E11 Three-digit 7-segment display shows E11 | Open rollout switch | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| b0 Three-digit 7-segment display shows Eb0 (flowchart name B0) | Circulator blower motor not running | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| d0 Three-digit 7-segment display shows Ed0 | Data not yet on network | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces | π Call a pro |
| 1 flash Diagnostic LED seen through the blower door window | Ignition lockout (no flame) | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π§ Check first |
| 2 flashes Diagnostic LED seen through the blower door window | Pressure switch stuck closed | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| 3 flashes Diagnostic LED seen through the blower door window | Pressure switch stuck open | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| 4 flashes Diagnostic LED seen through the blower door window | Open primary or auxiliary limit | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π§ Check first |
| 5 flashes Diagnostic LED seen through the blower door window | Flame sensed with no call for heat | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| 6 flashes Diagnostic LED seen through the blower door window | Open rollout limit | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| 7 flashes Diagnostic LED seen through the blower door window | Low flame sense signal | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| 8 flashes Diagnostic LED seen through the blower door window | Igniter circuit fault or poor ground | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |
| Continuous flash Diagnostic LED seen through the blower door window | Reversed polarity or poor ground (continuous or rapid flash) | Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control) | π Call a pro |