Goodman Furnace Continuous flash: Reversed polarity or poor ground (continuous or rapid flash)

Updated October 2026 Β· Sourced from Goodman documentation

πŸ›‘ Turn it off and call a licensed pro

The LED flashes continuously or rapidly and the furnace will not operate. The manual lists reversed 115 or 24 volt polarity, swapped orange and gray transformer wires or a poor unit ground.

Is it safe to keep running? No. Turn it off and get it checked. Turn the furnace off at the breaker and call a licensed technician or electrician to correct the wiring and ground.

Continuous flash at a glance

Code / how it showsMeaningApplies to
Continuous flash
Diagnostic LED seen through the blower door window
Reversed polarity or poor ground (continuous or rapid flash)Goodman GMS8 / Amana AMS8 / GDS8 / ADSS8 80% single-stage gas furnaces (older flash-code control)

πŸ›‘ Stop and call a licensed pro if

  • Turn the furnace off at the breaker and call a licensed technician or electrician to correct the wiring and ground.
  • You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
  • Flame rollout, limit or pressure switch codes that come back after one reset.
  • Anything involving the control board, gas valve, flame sensor, igniter or venting.
  • A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.

Safe first steps for any Goodman code

  1. Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
  2. Replace or clean the furnace air filter.
  3. Check the thermostat: correct mode, set above room temperature, and fresh batteries.
  4. Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
  5. Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
  6. On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).

Source: Goodman GMS8/AMS8/GDS8/ADSS8 80% Single Stage Service Instructions RS6612006 (July 2013), pp.37-39. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician

Related Goodman codes

1 flash : Ignition lockout (no flame)2 flashes : Pressure switch stuck closed3 flashes : Pressure switch stuck open4 flashes : Open primary or auxiliary limit5 flashes : Flame sensed with no call for heat6 flashes : Open rollout limit7 flashes : Low flame sense signal8 flashes : Igniter circuit fault or poor groundE0 : Lockout after three failed ignition attemptsE1 : Low-stage pressure switch closed at start of heatingE2 : Low-stage pressure switch circuit openE3 : Primary limit circuit open (furnace overheating)

All 28 Goodman codes and series β†’

← All HVAC and water heater codesAsk an HVAC technician