Goodman E6 Error Code: Weak flame sense signal
Updated October 2026 Β· Sourced from Goodman documentation
The flame sense micro amp signal is low. The furnace may still run normally, but the manual lists a coated or oxidized flame sensor, a sensor out of position or a lazy flame from improper gas pressure or combustion air.
Is it safe to keep running? No. Turn it off and get it checked. Book a service visit. Cleaning the flame sensor and checking gas pressure and venting should be done by a licensed technician.
E6 at a glance
| Code / how it shows | Meaning | Applies to |
|---|---|---|
| E6 Also: EE6 Three-digit 7-segment display shows EE6 | Weak flame sense signal | Goodman GMVC96 / Amana AMVC96 / GCVC96 / ACVC96 34.5-inch chassis two-stage gas furnaces |
Check this first
Only steps a homeowner can do safely. Do not open electrical panels or the burner area.
- Turn the furnace power off at the switch or breaker, wait one minute, then turn it back on to see whether the code returns.
- Look outside at the furnace vent and intake pipe ends. Make sure snow, leaves or a nest are not blocking them. Look only, do not touch the pipes.
π Stop and call a licensed pro if
- Book a service visit. Cleaning the flame sensor and checking gas pressure and venting should be done by a licensed technician.
- You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
- Flame rollout, limit or pressure switch codes that come back after one reset.
- Anything involving the control board, gas valve, flame sensor, igniter or venting.
- A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.
Safe first steps for any Goodman code
- Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
- Replace or clean the furnace air filter.
- Check the thermostat: correct mode, set above room temperature, and fresh batteries.
- Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
- Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
- On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).
Source: Goodman 34.5 in. Chassis ACVC96/AMVC96/GCVC96/GMVC96 Service and Troubleshooting RS6612023R2, p.42 (table) and p.51 (flowchart). Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.
Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician