Trane and American Standard Furnace Error Codes

Trane and American Standard gas furnaces share platforms. The control board LED blinks a set number of times to report a fault, visible through the blower door window. Below are 31 Trane and American Standard codes across 4 model series. Each one says what it means, which series it applies to, what you can safely check, and when to call a licensed pro, with a link to the Trane and American Standard document it comes from.

The same code can mean different things on different series, so match the series column to your unit. Your unit's manual is the final word. Reviewed October 2026.

39 codes

Trane and American Standard 2 flashesSystem lockout, retries or recycles exceededTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 2 flashesFlame lost or ignition failureTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 3 flashesPressure switch faultTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 3 flashesPressure switch failureTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 4 flashesOpen limit switchTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 4 flashesHigh temperature limit faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 5 flashesFlame sensed when none should be presentTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 5 flashesFlame detected when it should not beTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 6 flashes115 volt power reversed or improper groundTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 6 flashesLine polarity, ground or igniter faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 7 flashesGas valve circuit errorTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 7 flashesGas valve faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 8 flashesLow flame sense signalTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 8 flashesLow flame signalTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 9 flashesIgniter relay faultTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)Trane and American Standard 9 flashesFlue gas temperature too highTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard 10 flashesCommunication faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)Trane and American Standard E2.1Retry exceeded (flame never sensed)Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E2.2Recycles exceeded (flame lost)Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E3.1Shorted pressure switch, 1st stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E3.2Open pressure switch, 1st stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E3.4Open pressure switch, 2nd stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E04Open limitTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E05Flame detected, should not be presentTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E6.1Voltage reversed polarityTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E6.2Bad groundingTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E6.3Igniter relay fails or igniter openTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E08Low flame currentTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E12Open fuseTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesTrane and American Standard E1Shorted pressure switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard E2Open pressure switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard E5Open thermal limit or rollout switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard E6Open limit or rollout (after 5 times)Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard E7Ignition failure, locked outTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard E8Flame loss, locked outTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard FLFlame lowTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard FEGas valve relay stuck closedTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard PrPower reversedTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)Trane and American Standard FoFuse openTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)

All Trane and American Standard error codes

CodeMeaningApplies toSafety
2 flashes
Red LED on the integrated furnace control blinks 2 times, then pauses
System lockout, retries or recycles exceededTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)🧭 Check first
2 flashes
Red fault LED on the integrated furnace control blinks 2 times
Flame lost or ignition failureTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)🧭 Check first
3 flashes
Red LED on the integrated furnace control blinks 3 times, then pauses
Pressure switch faultTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
3 flashes
Red fault LED on the integrated furnace control blinks 3 times
Pressure switch failureTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)πŸ›‘ Call a pro
4 flashes
Red LED on the integrated furnace control blinks 4 times, then pauses
Open limit switchTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)🧭 Check first
4 flashes
Red fault LED on the integrated furnace control blinks 4 times
High temperature limit faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)🧭 Check first
5 flashes
Red LED on the integrated furnace control blinks 5 times, then pauses
Flame sensed when none should be presentTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
5 flashes
Red fault LED on the integrated furnace control blinks 5 times
Flame detected when it should not beTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)πŸ›‘ Call a pro
6 flashes
Red LED on the integrated furnace control blinks 6 times, then pauses
115 volt power reversed or improper groundTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
6 flashes
Red fault LED on the integrated furnace control blinks 6 times
Line polarity, ground or igniter faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)πŸ›‘ Call a pro
7 flashes
Red LED on the integrated furnace control blinks 7 times, then pauses
Gas valve circuit errorTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
7 flashes
Red fault LED on the integrated furnace control blinks 7 times
Gas valve faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)πŸ›‘ Call a pro
8 flashes
Red LED on the integrated furnace control blinks 8 times, then pauses
Low flame sense signalTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
8 flashes
Red fault LED on the integrated furnace control blinks 8 times
Low flame signalTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)🧭 Check first
9 flashes
Red LED on the integrated furnace control blinks 9 times, then pauses
Igniter relay faultTrane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)πŸ›‘ Call a pro
9 flashes
Red fault LED on the integrated furnace control blinks 9 times
Flue gas temperature too highTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)🧭 Check first
10 flashes
Red fault LED on the integrated furnace control blinks 10 times
Communication faultTrane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)🧭 Check first
E2.1
Shown on the 7-segment display of the integrated furnace control
Retry exceeded (flame never sensed)Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces🧭 Check first
E2.2
Shown on the 7-segment display of the integrated furnace control
Recycles exceeded (flame lost)Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces🧭 Check first
E3.1
Shown on the 7-segment display of the integrated furnace control
Shorted pressure switch, 1st stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E3.2
Shown on the 7-segment display of the integrated furnace control
Open pressure switch, 1st stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E3.4
Shown on the 7-segment display of the integrated furnace control
Open pressure switch, 2nd stageTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E04
Shown on the 7-segment display of the integrated furnace control
Open limitTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces🧭 Check first
E05
Shown on the 7-segment display of the integrated furnace control
Flame detected, should not be presentTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E6.1
Shown on the 7-segment display of the integrated furnace control
Voltage reversed polarityTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E6.2
Shown on the 7-segment display of the integrated furnace control
Bad groundingTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E6.3
Shown on the 7-segment display of the integrated furnace control
Igniter relay fails or igniter openTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E08
Shown on the 7-segment display of the integrated furnace control
Low flame currentTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces🧭 Check first
E12
Shown on the 7-segment display of the integrated furnace control
Open fuseTrane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnacesπŸ›‘ Call a pro
E1
Error code on the control display, with the red diagnostic LED blinking
Shorted pressure switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro
E2
Error code on the control display, with the red diagnostic LED blinking
Open pressure switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro
E5
Error code on the control display, with the red diagnostic LED blinking
Open thermal limit or rollout switchTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)🧭 Check first
E6
Error code on the control display, with the red diagnostic LED blinking
Open limit or rollout (after 5 times)Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro
E7
Error code on the control display, with the red diagnostic LED blinking
Ignition failure, locked outTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)🧭 Check first
E8
Error code on the control display, with the red diagnostic LED blinking
Flame loss, locked outTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)🧭 Check first
FL
Error code on the control display, with the red diagnostic LED blinking
Flame lowTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)🧭 Check first
FE
Error code on the control display, with the red diagnostic LED blinking
Gas valve relay stuck closedTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro
Pr
Error code on the control display, with the red diagnostic LED blinking
Power reversedTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro
Fo
Error code on the control display, with the red diagnostic LED blinking
Fuse openTrane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)πŸ›‘ Call a pro

βœ… Usually fine to keep running Β· 🧭 Check a few things first Β· πŸ›‘ Turn it off and call a licensed pro

Find your Trane and American Standard model series

The codes Trane and American Standard documents for each series we have checked. If your series is not listed, the code may mean something different on your unit, so check its manual.

Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models)

Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models)

Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951)

Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces

More Trane and American Standard codes

Trane and American Standard 5 flashes: Flame sensed when none should be present

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951). Shows as: Red LED on the integrated furnace control blinks 5 times, then pauses

The control senses flame when no flame should be present.

When to call a pro: Call a licensed HVAC technician right away.

Source: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 5 times

The control detects flame when it should not be present.

When to call a pro: Call a licensed HVAC technician right away.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard 6 flashes: 115 volt power reversed or improper ground

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951). Shows as: Red LED on the integrated furnace control blinks 6 times, then pauses

The control reports 115 volt AC power is reversed or the furnace has an improper ground. This is a wiring fault.

When to call a pro: Call a licensed HVAC technician. Line voltage wiring and grounding must be fixed by a professional.

Source: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 6 times

This flash count covers reversed voltage polarity, a missing earth ground, or an igniter or triac fault.

When to call a pro: Call a licensed HVAC technician. Wiring, grounding and igniter faults need professional repair.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard 7 flashes: Gas valve circuit error

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951). Shows as: Red LED on the integrated furnace control blinks 7 times, then pauses

The control reports a gas valve circuit error.

When to call a pro: Call a licensed HVAC technician to inspect the gas valve circuit.

Source: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 7 times

The control either senses 24V at the gas valve when it should not be there, or tried to turn the valve on and did not sense 24V.

When to call a pro: Call a licensed HVAC technician to inspect the gas valve circuit.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard 8 flashes: Low flame sense signal

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951). Shows as: Red LED on the integrated furnace control blinks 8 times, then pauses

The control reports a low flame sense signal.

When to call a pro: Call a licensed HVAC technician. Flame sensor service and grounding checks are for a professional.

Source: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes

🧭 Check a few things first

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 8 times

Flame current is low, but still strong enough to allow operation.

When to call a pro: Call a licensed HVAC technician. A flame sensor must be serviced by a professional.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard 9 flashes: Igniter relay fault

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951). Shows as: Red LED on the integrated furnace control blinks 9 times, then pauses

The control reports an igniter relay fault.

When to call a pro: Call a licensed HVAC technician to test the igniter circuit and control.

Source: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes

🧭 Check a few things first

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 9 times

The flue gas temperature is too high. The manual says this could be caused by low airflow or fan failure.

When to call a pro: Call a licensed HVAC technician if it repeats.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard 10 flashes: Communication fault

🧭 Check a few things first

Applies to: Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models). Shows as: Red fault LED on the integrated furnace control blinks 10 times

This group covers communication problems between the control, inducer motor, blower motor and system, including loss of heat or cool demand.

When to call a pro: Call a licensed HVAC technician if the furnace and thermostat will not communicate.

Source: Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55

Trane and American Standard E2.2: Recycles exceeded (flame lost)

🧭 Check a few things first

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

Flame was sensed and then lost. The control locks out for one hour after 10 times.

When to call a pro: Call a licensed HVAC technician if it locks out again.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E3.1: Shorted pressure switch, 1st stage

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

The first stage pressure switch is shorted.

When to call a pro: Call a licensed HVAC technician to test the pressure switch and inducer.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E3.4: Open pressure switch, 2nd stage

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

The second stage pressure switch is open. This applies to the S8X2 only.

When to call a pro: Call a licensed HVAC technician.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E05: Flame detected, should not be present

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

The control senses flame when none should be present.

When to call a pro: Call a licensed HVAC technician right away.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E6.3: Igniter relay fails or igniter open

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

The control reports either the igniter relay failing or the igniter being open.

When to call a pro: Call a licensed HVAC technician to test the igniter.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E08: Low flame current

🧭 Check a few things first

Applies to: Trane S8B1 and S8X1 (single stage) and S8X2 (two stage) gas furnaces. Shows as: Shown on the 7-segment display of the integrated furnace control

Flame current is low, but still strong enough to allow operation.

When to call a pro: Call a licensed HVAC technician. Flame sensor service is for a professional.

Source: Trane Installer's Guide 18-CE14D1-1A-EN (04/2020), Integrated Furnace Control Display Codes, p.58

Trane and American Standard E1: Shorted pressure switch

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

The pressure switch is stuck closed. The manual says to check the switch function and verify the inducer is turning off.

When to call a pro: Call a licensed HVAC technician.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard E2: Open pressure switch

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

The pressure switch is open. The manual says to check the switch function and tubing, and verify the inducer is pulling enough vacuum to engage the switch.

When to call a pro: Call a licensed HVAC technician for pressure switch and inducer checks.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard E6: Open limit or rollout (after 5 times)

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

A thermal limit or rollout switch opened repeatedly (after 5 times).

When to call a pro: Call a licensed HVAC technician.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard E8: Flame loss, locked out

🧭 Check a few things first

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

Flame was lost repeatedly and the control locked out.

When to call a pro: Call a licensed HVAC technician.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard FL: Flame low

🧭 Check a few things first

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

The flame sense current is low. The manual lists carbon on the flame sensor, poor grounding or a misaligned sensor as causes.

When to call a pro: Call a licensed HVAC technician to service the flame sensor.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard FE: Gas valve relay stuck closed

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

The gas valve relay is stuck closed. The manual says to verify the gas valve operates and shuts down properly.

When to call a pro: Call a licensed HVAC technician right away.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard Pr: Power reversed

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

Power polarity is reversed. The manual says to verify the control and furnace are properly grounded and reverse polarity if incorrect.

When to call a pro: Call a licensed HVAC technician.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Trane and American Standard Fo: Fuse open

πŸ›‘ Turn it off and call a licensed pro

Applies to: Trane and American Standard A801X high efficiency gas furnaces (A801X060AM3S and related models). Shows as: Error code on the control display, with the red diagnostic LED blinking

The low voltage fuse is open, indicating a low voltage over-current condition. The manual says to locate the shorted wiring or component.

When to call a pro: Call a licensed HVAC technician to find the short.

Source: Trane Installation Manual 88-A801X004-1B-EN (11/2024), Table 13-1 Troubleshooting Chart, p.32

Safe first steps for any code

  1. Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
  2. Replace or clean the furnace air filter.
  3. Check the thermostat: correct mode, set above room temperature, and fresh batteries.
  4. Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
  5. Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
  6. On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).

πŸ›‘ Stop and call a licensed pro if

  • You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
  • Flame rollout, limit or pressure switch codes that come back after one reset.
  • Anything involving the control board, gas valve, flame sensor, igniter or venting.
  • A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician