Trane and American Standard Furnace 2 flashes: System lockout, retries or recycles exceeded
Updated October 2026 Β· Sourced from Trane and American Standard documentation
Trane and American Standard 2 flashes means different things on different series:
- Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951): The control locked out after too many ignition retries or recycles. Trane says the control resets itself after a one hour lockout, or you can reset it by interrupting power or cycling the thermostat.
- Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models): The flame went out when it should have been on, or the furnace tried to light and no flame was detected. The manual says 10 recycles in one call for heat, or 3 ignition attempts in a row, cause a 1 hour lockout.
Is it safe to keep running? Check the steps below first. Call a licensed HVAC technician if the lockout returns. Igniter, flame sensor, pressure switch and gas valve checks are for a professional.
2 flashes at a glance
| Code / how it shows | Meaning | Applies to |
|---|---|---|
| 2 flashes Red LED on the integrated furnace control blinks 2 times, then pauses | System lockout, retries or recycles exceeded | Trane and American Standard single-stage furnaces serviced with the SiNi igniter control kit (*UH1, *DH1, *UD1, *DD1 families and M951) |
| 2 flashes Red fault LED on the integrated furnace control blinks 2 times | Flame lost or ignition failure | Trane and American Standard modulating communicating *UHM/*DHM furnaces (e.g. *UHMB060ACV3VB, *UHMC100ACV4VB, *UHMD120ACV5VB and matching DHM models) |
Check this first
Only steps a homeowner can do safely. Do not open electrical panels or the burner area.
- Make sure the manual gas valve to the furnace is on (handle in line with the pipe), following the lighting instructions on the furnace label.
- Turn the furnace power off for 20 seconds, then back on, or lower the thermostat for a short time and raise it again.
- Check the thermostat is set to Heat, set above room temperature, and has fresh batteries if it uses them.
- Look outside at the furnace vent and intake pipes for snow, leaves, nests or other blockage, and clear anything you can reach safely.
- Turn the furnace power switch or breaker off for 30 seconds, then back on, and see if the code clears.
π Stop and call a licensed pro if
- Call a licensed HVAC technician if the lockout returns. Igniter, flame sensor, pressure switch and gas valve checks are for a professional.
- Call a licensed HVAC technician if it locks out again. Igniter and flame sensor service is for a professional.
- You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
- Flame rollout, limit or pressure switch codes that come back after one reset.
- Anything involving the control board, gas valve, flame sensor, igniter or venting.
- A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.
Safe first steps for any Trane and American Standard code
- Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
- Replace or clean the furnace air filter.
- Check the thermostat: correct mode, set above room temperature, and fresh batteries.
- Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
- Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
- On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).
Sources: Trane Service Installer's Guide 18-CH93D1-1A-EN (Jul 2020), Integrated Furnace Control Diagnostic Codes; Trane Installer's Guide 18-CD30D1-20-EN (06/2020), Table 24 Furnace Alert Codes, p.55. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.
Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician