| 03 110/310: red LED on the computer board blinks one time. Remote controller shows 03. 510 (T-D2): 7-segment display shows 031 | Incorrect DIP switch setting | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 10 110/310: red LED on the computer board blinks five times. Remote controller shows 10. 510 (T-D2): 7-segment display shows 101 | Warning for the 991 code (air or exhaust problem) | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π§ Check first |
| 10 Error code flashes on the temperature controller display | Air supply or exhaust blockage | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π§ Check first |
| 11 110/310: red LED on the computer board blinks three times. Remote controller shows 11. 510 (T-D2): 7-segment display shows 111 | Ignition failure | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 11 Error code flashes on the temperature controller display | No ignition | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 12 110/310: red LED on the computer board blinks three times. Remote controller shows 12. 510 (T-D2): 7-segment display shows 121 | Loss of flame | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 12 Error code flashes on the temperature controller display | Flame failure | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 31 110/310: red LED on the computer board blinks two times. Remote controller shows 31. 510 (T-D2): 7-segment display shows 311 | Outlet thermistor failure | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 32 110/310: red LED on the computer board blinks two times. Remote controller shows 32. 510 (T-D2): 7-segment display shows 321 | Inlet thermistor failure | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 61 110/310: red LED on the computer board blinks four times. Remote controller shows 61. 510 (T-D2): 7-segment display shows 611 | Fan motor fault | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 61 Error code flashes on the temperature controller display | Combustion fan failure | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 72 110/310: red LED on the computer board blinks six times. Remote controller shows 72. 510 (T-D2): 7-segment display shows 721 | False flame detection | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π Call a pro |
| 72 Error code flashes on the temperature controller display | Flame sensing device fault | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 74 110/310: no blink pattern listed (N/A). Remote controller shows 74. 510 (T-D2): remote shows 741 | Remote controller communication error | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π§ Check first |
| 99 110/310: red LED on the computer board blinks five times. Remote controller shows 99. 510 (T-D2): 7-segment display shows 991 | Imperfect combustion | A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters | π§ Check first |
| 02 Error code flashes on the temperature controller display | No burner operation in freeze protection mode | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 14 Error code flashes on the temperature controller display | Thermal fuse | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π Call a pro |
| 16 Error code flashes on the temperature controller display | Over temperature warning | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π§ Check first |
| LC Error code flashes on the temperature controller display | Scale build-up in heat exchanger | A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters | π§ Check first |
| 2 flashes Gas control valve status light flashes, then a pause | Thermopile voltage low | A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light | π Call a pro |
| 4 flashes Gas control valve status light flashes, then a pause | Overheat failure | A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light | π Call a pro |
| 5 flashes Gas control valve status light flashes, then a pause | Sensor failure | A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light | π Call a pro |
| 7 flashes Gas control valve status light flashes, then a pause | Electronic control failure | A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light | π Call a pro |
| 8 flashes Gas control valve status light flashes, then a pause | Pilot or thermopile still active with the knob off | A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light | π Call a pro |
| SF Shown on the water heater display | Air filter is dirty | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π§ Check first |
| ECF Shown on the water heater display | Heat pump compressor starting and stopping often | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π§ Check first |
| Edr Shown on the water heater display | Not enough water in tank (dry fire) | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π§ Check first |
| EPL Shown on the water heater display | Power supply voltage too low | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π§ Check first |
| EUC Shown on the water heater display | Upper element not functioning | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π Call a pro |
| ELC Shown on the water heater display | Lower element not functioning | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | π Call a pro |
| ICE Shown on the water heater display | Heat pump is defrosting | A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085 | β
Keep running |