A. O. Smith Water Heater Error Codes

A. O. Smith tank water heaters flash a status light on the gas control a set number of times, and tankless and hybrid models show a code on the display. Below are 26 A. O. Smith codes across 4 model series. Each one says what it means, which series it applies to, what you can safely check, and when to call a licensed pro, with a link to the A. O. Smith document it comes from.

The same code can mean different things on different series, so match the series column to your unit. Your unit's manual is the final word. Reviewed October 2026.

31 codes

A. O. Smith 03Incorrect DIP switch settingA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 10Warning for the 991 code (air or exhaust problem)A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 10Air supply or exhaust blockageA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 11Ignition failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 11No ignitionA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 12Loss of flameA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 12Flame failureA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 31Outlet thermistor failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 32Inlet thermistor failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 61Fan motor faultA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 61Combustion fan failureA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 72False flame detectionA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 72Flame sensing device faultA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 74Remote controller communication errorA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 99Imperfect combustionA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersA. O. Smith 02No burner operation in freeze protection modeA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 14Thermal fuseA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 16Over temperature warningA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith LCScale build-up in heat exchangerA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersA. O. Smith 2 flashesThermopile voltage lowA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightA. O. Smith 4 flashesOverheat failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightA. O. Smith 5 flashesSensor failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightA. O. Smith 7 flashesElectronic control failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightA. O. Smith 8 flashesPilot or thermopile still active with the knob offA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightA. O. Smith SFAir filter is dirtyA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith ECFHeat pump compressor starting and stopping oftenA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith EdrNot enough water in tank (dry fire)A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith EPLPower supply voltage too lowA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith EUCUpper element not functioningA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith ELCLower element not functioningA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085A. O. Smith ICEHeat pump is defrostingA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085

All A. O. Smith error codes

CodeMeaningApplies toSafety
03
110/310: red LED on the computer board blinks one time. Remote controller shows 03. 510 (T-D2): 7-segment display shows 031
Incorrect DIP switch settingA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
10
110/310: red LED on the computer board blinks five times. Remote controller shows 10. 510 (T-D2): 7-segment display shows 101
Warning for the 991 code (air or exhaust problem)A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters🧭 Check first
10
Error code flashes on the temperature controller display
Air supply or exhaust blockageA. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters🧭 Check first
11
110/310: red LED on the computer board blinks three times. Remote controller shows 11. 510 (T-D2): 7-segment display shows 111
Ignition failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
11
Error code flashes on the temperature controller display
No ignitionA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
12
110/310: red LED on the computer board blinks three times. Remote controller shows 12. 510 (T-D2): 7-segment display shows 121
Loss of flameA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
12
Error code flashes on the temperature controller display
Flame failureA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
31
110/310: red LED on the computer board blinks two times. Remote controller shows 31. 510 (T-D2): 7-segment display shows 311
Outlet thermistor failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
32
110/310: red LED on the computer board blinks two times. Remote controller shows 32. 510 (T-D2): 7-segment display shows 321
Inlet thermistor failureA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
61
110/310: red LED on the computer board blinks four times. Remote controller shows 61. 510 (T-D2): 7-segment display shows 611
Fan motor faultA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
61
Error code flashes on the temperature controller display
Combustion fan failureA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
72
110/310: red LED on the computer board blinks six times. Remote controller shows 72. 510 (T-D2): 7-segment display shows 721
False flame detectionA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heatersπŸ›‘ Call a pro
72
Error code flashes on the temperature controller display
Flame sensing device faultA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
74
110/310: no blink pattern listed (N/A). Remote controller shows 74. 510 (T-D2): remote shows 741
Remote controller communication errorA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters🧭 Check first
99
110/310: red LED on the computer board blinks five times. Remote controller shows 99. 510 (T-D2): 7-segment display shows 991
Imperfect combustionA. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters🧭 Check first
02
Error code flashes on the temperature controller display
No burner operation in freeze protection modeA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
14
Error code flashes on the temperature controller display
Thermal fuseA. O. Smith 305, 505 and 705 direct vent indoor tankless water heatersπŸ›‘ Call a pro
16
Error code flashes on the temperature controller display
Over temperature warningA. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters🧭 Check first
LC
Error code flashes on the temperature controller display
Scale build-up in heat exchangerA. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters🧭 Check first
2 flashes
Gas control valve status light flashes, then a pause
Thermopile voltage lowA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightπŸ›‘ Call a pro
4 flashes
Gas control valve status light flashes, then a pause
Overheat failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightπŸ›‘ Call a pro
5 flashes
Gas control valve status light flashes, then a pause
Sensor failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightπŸ›‘ Call a pro
7 flashes
Gas control valve status light flashes, then a pause
Electronic control failureA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightπŸ›‘ Call a pro
8 flashes
Gas control valve status light flashes, then a pause
Pilot or thermopile still active with the knob offA. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status lightπŸ›‘ Call a pro
SF
Shown on the water heater display
Air filter is dirtyA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085🧭 Check first
ECF
Shown on the water heater display
Heat pump compressor starting and stopping oftenA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085🧭 Check first
Edr
Shown on the water heater display
Not enough water in tank (dry fire)A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085🧭 Check first
EPL
Shown on the water heater display
Power supply voltage too lowA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085🧭 Check first
EUC
Shown on the water heater display
Upper element not functioningA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085πŸ›‘ Call a pro
ELC
Shown on the water heater display
Lower element not functioningA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085πŸ›‘ Call a pro
ICE
Shown on the water heater display
Heat pump is defrostingA. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085βœ… Keep running

βœ… Usually fine to keep running Β· 🧭 Check a few things first Β· πŸ›‘ Turn it off and call a licensed pro

Find your A. O. Smith model series

The codes A. O. Smith documents for each series we have checked. If your series is not listed, the code may mean something different on your unit, so check its manual.

A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters

A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters

A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light

A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085

More A. O. Smith codes

A. O. Smith 03: Incorrect DIP switch setting

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: red LED on the computer board blinks one time. Remote controller shows 03. 510 (T-D2): 7-segment display shows 031

The manual lists this as: Incorrect DIPswitch setting.

When to call a pro: The DIP switches are on the circuit board. Have a qualified installer or service technician check the settings.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 44

A. O. Smith 31: Outlet thermistor failure

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: red LED on the computer board blinks two times. Remote controller shows 31. 510 (T-D2): 7-segment display shows 311

The manual lists this as: Outlet thermistor failure.

When to call a pro: Call a licensed service pro. The manual says to consult the manufacturer after the listed checks, and these are gas, electrical or board parts.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 44

A. O. Smith 32: Inlet thermistor failure

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: red LED on the computer board blinks two times. Remote controller shows 32. 510 (T-D2): 7-segment display shows 321

The manual lists this as: Inlet thermistor failure.

When to call a pro: Call a licensed service pro. The manual says to consult the manufacturer after the listed checks, and these are gas, electrical or board parts.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 44

A. O. Smith 61: Fan motor fault

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: red LED on the computer board blinks four times. Remote controller shows 61. 510 (T-D2): 7-segment display shows 611

The manual lists this as: Fan motor fault.

When to call a pro: Call a licensed service pro. The manual says to consult the manufacturer after the listed checks, and these are gas, electrical or board parts.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 45

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters. Shows as: Error code flashes on the temperature controller display

The manual lists this as combustion fan failure.

When to call a pro: Call a licensed pro. The manual warns that some remedies involve gas or electricity and need a qualified service technician.

Source: A. O. Smith Direct Vent Tankless Water Heater Operation and Installation Manual (305, 505, 705 Indoor), Error Code Table, p. 10

A. O. Smith 72: False flame detection

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: red LED on the computer board blinks six times. Remote controller shows 72. 510 (T-D2): 7-segment display shows 721

The manual lists this as: False flame detection.

When to call a pro: Call a licensed pro. The manual says to check the condensate drain on the vent collar and for heat exchanger leaks.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 45

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters. Shows as: Error code flashes on the temperature controller display

The manual lists this as a flame sensing device (flame rod) fault.

When to call a pro: Call a licensed pro. The manual warns that some remedies involve gas or electricity and need a qualified service technician.

Source: A. O. Smith Direct Vent Tankless Water Heater Operation and Installation Manual (305, 505, 705 Indoor), Error Code Table, p. 10

A. O. Smith 74: Remote controller communication error

🧭 Check a few things first

Applies to: A. O. Smith 110 (T-KJr2), 310 (T-K4) and 510 (T-D2) tankless water heaters. Shows as: 110/310: no blink pattern listed (N/A). Remote controller shows 74. 510 (T-D2): remote shows 741

The manual lists this as: Miscommunication between water heater and remote controller.

When to call a pro: If the remote still cannot communicate, call a qualified service technician to check the controller model and connections.

Source: A. O. Smith On-Demand Water Heater Installation Manual and Owner's Guide (110, 310, 510 models), Fault Analysis of Error Codes, p. 45

A. O. Smith 02: No burner operation in freeze protection mode

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters. Shows as: Error code flashes on the temperature controller display

The manual lists this as no burner operation during freeze protection mode, with the remedy "Service Call".

When to call a pro: The manual's remedy is a service call.

Source: A. O. Smith Direct Vent Tankless Water Heater Operation and Installation Manual (305, 505, 705 Indoor), Error Code Table, p. 9

A. O. Smith 14: Thermal fuse

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters. Shows as: Error code flashes on the temperature controller display

The manual lists this as a thermal fuse fault.

When to call a pro: Call a licensed pro. The manual warns that some remedies involve gas or electricity and need a qualified service technician.

Source: A. O. Smith Direct Vent Tankless Water Heater Operation and Installation Manual (305, 505, 705 Indoor), Error Code Table, p. 10

A. O. Smith 16: Over temperature warning

🧭 Check a few things first

Applies to: A. O. Smith 305, 505 and 705 direct vent indoor tankless water heaters. Shows as: Error code flashes on the temperature controller display

The manual lists this as an over temperature warning.

When to call a pro: Call a licensed pro if the warning returns. The manual lists low circulating flow, debris and a clogged heat exchanger as causes to check.

Source: A. O. Smith Direct Vent Tankless Water Heater Operation and Installation Manual (305, 505, 705 Indoor), Error Code Table, p. 10

A. O. Smith 5 flashes: Sensor failure

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light. Shows as: Gas control valve status light flashes, then a pause

Five flashes indicate a sensor failure in the gas control valve/thermostat.

When to call a pro: The chart says to replace the gas control valve/thermostat. Call a licensed pro.

Source: A. O. Smith Direct Vent Residential Gas Water Heater Installation Instructions and Use & Care Guide (Ultra Low NOx), Status Light Code, p. 21 and 30

A. O. Smith 7 flashes: Electronic control failure

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light. Shows as: Gas control valve status light flashes, then a pause

Seven flashes indicate a failure of the electronic control in the gas control valve/thermostat.

When to call a pro: The chart says to replace the gas control valve/thermostat. Call a licensed pro.

Source: A. O. Smith Direct Vent Residential Gas Water Heater Installation Instructions and Use & Care Guide (Ultra Low NOx), Status Light Code, p. 21 and 30

A. O. Smith 8 flashes: Pilot or thermopile still active with the knob off

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith Direct Vent Residential Gas tank water heaters (Ultra Low NOx models) with gas control valve/thermostat status light. Shows as: Gas control valve status light flashes, then a pause

Eight flashes appear only if the temperature knob has been turned off and the thermopile still produces power, for example because the pilot valve is stuck open.

When to call a pro: The chart says to replace the gas control valve/thermostat if the pilot stays lit with the knob off. Call a licensed pro.

Source: A. O. Smith Direct Vent Residential Gas Water Heater Installation Instructions and Use & Care Guide (Ultra Low NOx), Status Light Code, p. 21 and 30

A. O. Smith ECF: Heat pump compressor starting and stopping often

🧭 Check a few things first

Applies to: A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085. Shows as: Shown on the water heater display

The guide says the heat pump compressor is starting and stopping frequently.

When to call a pro: The guide says that if the error persists, contact a qualified person to check the fan wire connection.

Source: A. O. Smith Hybrid Electric Heat Pump Water Heater Use and Care Guide 100269085, Diagnostic Codes, p. 20

A. O. Smith EPL: Power supply voltage too low

🧭 Check a few things first

Applies to: A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085. Shows as: Shown on the water heater display

The guide says the power supply voltage is too low.

When to call a pro: Call a licensed electrician or qualified person to check the supply voltage.

Source: A. O. Smith Hybrid Electric Heat Pump Water Heater Use and Care Guide 100269085, Diagnostic Codes, p. 21

A. O. Smith EUC: Upper element not functioning

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085. Shows as: Shown on the water heater display

The guide says the upper heating element is not functioning.

When to call a pro: The guide says to check for a loose connection at the element and replace a failed element. Call a qualified person.

Source: A. O. Smith Hybrid Electric Heat Pump Water Heater Use and Care Guide 100269085, Diagnostic Codes, p. 20

A. O. Smith ELC: Lower element not functioning

πŸ›‘ Turn it off and call a licensed pro

Applies to: A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085. Shows as: Shown on the water heater display

The guide says the lower heating element is not functioning.

When to call a pro: The guide says to check for a loose connection at the element and replace a failed element. Call a qualified person.

Source: A. O. Smith Hybrid Electric Heat Pump Water Heater Use and Care Guide 100269085, Diagnostic Codes, p. 20

A. O. Smith ICE: Heat pump is defrosting

βœ… Usually fine to keep running

Applies to: A. O. Smith Hybrid Electric Heat Pump water heaters (Voltex), Installation Instructions and Use & Care Guide 100269085. Shows as: Shown on the water heater display

The guide says this means the heat pump is in a defrosting cycle. It is normal operation.

When to call a pro: Call a qualified person only if the unit never leaves this state.

Source: A. O. Smith Hybrid Electric Heat Pump Water Heater Use and Care Guide 100269085, Diagnostic Codes, p. 20

Safe first steps for any code

  1. Write down the exact code shown on the controller or the number of status light flashes.
  2. Turn the water heater power off and back on (or press the reset button the manual describes) once. If the code comes back, stop resetting.
  3. Make sure the gas supply valve to the heater is open and other gas appliances in the home are working.
  4. Make sure the cold water supply valve is fully open and hot water taps are not partly closed.
  5. Look at the outside vent terminal for snow, ice, leaves or anything blocking it (look only).

πŸ›‘ Stop and call a licensed pro if

  • You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
  • Codes for flame failure, overheating, venting or the control board that return after one reset.
  • Water leaking from the heater, the relief valve discharging, or scorching around the burner area.
  • A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.