Mitsubishi Electric Mini-Split Error Codes

Mitsubishi Electric ductless units show a code such as E6, P8 or U2 on the remote controller, and wall units also blink the OPERATION lamp a set number of times. Below are 34 Mitsubishi Electric codes across 2 model series. Each one says what it means, which series it applies to, what you can safely check, and when to call a licensed pro, with a link to the Mitsubishi Electric document it comes from.

The same code can mean different things on different series, so match the series column to your unit. Your unit's manual is the final word. Reviewed October 2026.

34 codes

Mitsubishi Electric P1Intake (room) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P2Pipe (liquid) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P9Pipe (condenser/evaporator) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric E6Indoor/outdoor unit communication errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P4Float switch connector openPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P5Drain pump error (water leakage abnormality)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric PAForced compressor stopPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P6Freezing or overheating protection operationPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric EECommunication error between indoor and outdoor unitsPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric P8Pipe temperature errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric E4Remote controller signal receiving errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric FbIndoor unit control system errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric PLRefrigerant circuit abnormalPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric E1Remote controller control board errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric E0Remote controller transmission errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric E9Indoor/outdoor communication error (transmitting)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric UPCompressor overcurrent interruptionPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U3Outdoor unit thermistor open or shortPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric UFCompressor overcurrent (compressor locked)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U2High discharge temperature or insufficient refrigerantPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U1Abnormal high pressure or overheating protectionPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U5Abnormal heat sink temperaturePLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U8Outdoor unit fan protection stopPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U6Compressor overcurrent or power module abnormalPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U7Superheat abnormality (low discharge temperature)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric U9Overvoltage, voltage shortage or current sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)Mitsubishi Electric Lamp blinks 0.5 s on/offMiswiring or serial signal errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 2 blinksIndoor coil or room temperature thermistor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 3 blinksIndoor fan motor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 4 blinksIndoor control system errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 5 blinksOutdoor power system abnormalityMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 6 blinksOutdoor thermistor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 7 blinksOutdoor control system errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)Mitsubishi Electric 14 or more blinksOther abnormalityMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)

All Mitsubishi Electric error codes

CodeMeaningApplies toSafety
P1
Wireless remote: the OPERATION INDICATOR lamp flashes 1 times in a self-check; wired remote shows the code
Intake (room) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
P2
Wireless remote: the OPERATION INDICATOR lamp flashes 2 times in a self-check; wired remote shows the code
Pipe (liquid) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
P9
Wireless remote: the OPERATION INDICATOR lamp flashes 2 times in a self-check; wired remote shows the code
Pipe (condenser/evaporator) sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
E6
Wireless remote: the OPERATION INDICATOR lamp flashes 3 times in a self-check; wired remote shows the code
Indoor/outdoor unit communication errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
P4
Wireless remote: the OPERATION INDICATOR lamp flashes 4 times in a self-check; wired remote shows the code
Float switch connector openPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
P5
Wireless remote: the OPERATION INDICATOR lamp flashes 5 times in a self-check; wired remote shows the code
Drain pump error (water leakage abnormality)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
PA
Wireless remote: the OPERATION INDICATOR lamp flashes 5 times in a self-check; wired remote shows the code
Forced compressor stopPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
P6
Wireless remote: the OPERATION INDICATOR lamp flashes 6 times in a self-check; wired remote shows the code
Freezing or overheating protection operationPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
EE
Wireless remote: the OPERATION INDICATOR lamp flashes 7 times in a self-check; wired remote shows the code
Communication error between indoor and outdoor unitsPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
P8
Wireless remote: the OPERATION INDICATOR lamp flashes 8 times in a self-check; wired remote shows the code
Pipe temperature errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
E4
Wireless remote: the OPERATION INDICATOR lamp flashes 9 times in a self-check; wired remote shows the code
Remote controller signal receiving errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
Fb
Wireless remote: the OPERATION INDICATOR lamp flashes 12 times in a self-check; wired remote shows the code
Indoor unit control system errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
PL
Wireless remote: the OPERATION INDICATOR lamp flashes 13 times in a self-check; wired remote shows the code
Refrigerant circuit abnormalPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
E1
Shown on the remote controller (no fixed flash count in the table)
Remote controller control board errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
E0
Shown on the remote controller (no fixed flash count in the table)
Remote controller transmission errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
E9
Wireless remote: second self-check pattern (errors found by the outdoor unit), 1 flash; wired remote shows E9
Indoor/outdoor communication error (transmitting)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)🧭 Check first
UP
Second self-check pattern, 2 flashes
Compressor overcurrent interruptionPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U3
Second self-check pattern, 3 flashes
Outdoor unit thermistor open or shortPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
UF
Second self-check pattern, 4 flashes
Compressor overcurrent (compressor locked)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U2
Second self-check pattern, 5 flashes
High discharge temperature or insufficient refrigerantPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U1
Second self-check pattern, 6 flashes
Abnormal high pressure or overheating protectionPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U5
Second self-check pattern, 7 flashes
Abnormal heat sink temperaturePLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U8
Second self-check pattern, 8 flashes
Outdoor unit fan protection stopPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U6
Second self-check pattern, 9 flashes
Compressor overcurrent or power module abnormalPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U7
Second self-check pattern, 10 flashes
Superheat abnormality (low discharge temperature)PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
U9
Second self-check pattern, 11 flashes
Overvoltage, voltage shortage or current sensor errorPLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)πŸ›‘ Call a pro
Lamp blinks 0.5 s on/off
Left OPERATION INDICATOR lamp blinks ON and OFF at 0.5-second intervals
Miswiring or serial signal errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)🧭 Check first
2 blinks
Left OPERATION INDICATOR lamp blinks 2 times, then 2.5-second pause
Indoor coil or room temperature thermistor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)🧭 Check first
3 blinks
Left OPERATION INDICATOR lamp blinks 3 times, then 2.5-second pause
Indoor fan motor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)🧭 Check first
4 blinks
Left OPERATION INDICATOR lamp blinks 4 times, then 2.5-second pause
Indoor control system errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)πŸ›‘ Call a pro
5 blinks
Left OPERATION INDICATOR lamp blinks 5 times, then 2.5-second pause
Outdoor power system abnormalityMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)πŸ›‘ Call a pro
6 blinks
Left OPERATION INDICATOR lamp blinks 6 times, then 2.5-second pause
Outdoor thermistor errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)πŸ›‘ Call a pro
7 blinks
Left OPERATION INDICATOR lamp blinks 7 times, then 2.5-second pause
Outdoor control system errorMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)πŸ›‘ Call a pro
14 or more blinks
Left OPERATION INDICATOR lamp blinks 14 times or more
Other abnormalityMSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)πŸ›‘ Call a pro

βœ… Usually fine to keep running Β· 🧭 Check a few things first Β· πŸ›‘ Turn it off and call a licensed pro

Find your Mitsubishi Electric model series

The codes Mitsubishi Electric documents for each series we have checked. If your series is not listed, the code may mean something different on your unit, so check its manual.

MSZ-AP15VG / MSZ-AP20VG wall-mounted indoor units (OBH838 service manual)

PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual)

More Mitsubishi Electric codes

Mitsubishi Electric P1: Intake (room) sensor error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 1 times in a self-check; wired remote shows the code

The indoor unit reports an error with the intake air (room temperature) sensor.

When to call a pro: If P1 comes back after a power reset, a technician needs to check the sensor and its connector.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric P2: Pipe (liquid) sensor error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 2 times in a self-check; wired remote shows the code

The indoor unit reports an error with the pipe (TH2) temperature sensor.

When to call a pro: If it returns after a power reset, a technician needs to test the sensor and wiring.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric P9: Pipe (condenser/evaporator) sensor error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 2 times in a self-check; wired remote shows the code

The indoor unit reports an error with the pipe (TH5) temperature sensor. It shares the 2-flash pattern with P2.

When to call a pro: If it returns after a power reset, a technician needs to test the sensor and wiring.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric P4: Float switch connector open

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 4 times in a self-check; wired remote shows the code

The indoor unit reports that the float switch connector is open.

When to call a pro: Turn the unit off and call a technician. The float switch is part of the condensate protection inside the unit.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric PA: Forced compressor stop

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 5 times in a self-check; wired remote shows the code

The indoor unit reports a forced compressor stop. It shares the 5-flash pattern with P5.

When to call a pro: Turn the unit off and call a licensed technician.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric EE: Communication error between indoor and outdoor units

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 7 times in a self-check; wired remote shows the code

The indoor unit reports a communication error between the indoor and outdoor units.

When to call a pro: If it returns, a technician needs to check the connecting wiring and control boards.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric E4: Remote controller signal receiving error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 9 times in a self-check; wired remote shows the code

The indoor unit reports an error receiving the remote controller signal. The manual lists E4 and E5 together.

When to call a pro: If it returns, a technician needs to check the remote controller and indoor board.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric Fb: Indoor unit control system error

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 12 times in a self-check; wired remote shows the code

The indoor unit reports a control system error such as a memory error. A PAR-30MAA remote shows it as FB.

When to call a pro: The indoor control board likely needs service. Call a licensed technician.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric PL: Refrigerant circuit abnormal

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Wireless remote: the OPERATION INDICATOR lamp flashes 13 times in a self-check; wired remote shows the code

The indoor unit reports an abnormal refrigerant circuit.

When to call a pro: Turn the unit off and call a licensed technician. Refrigerant must only be handled by a technician.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric E1: Remote controller control board error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Shown on the remote controller (no fixed flash count in the table)

The remote controller reports a control board error. The manual lists E1 and E2 together.

When to call a pro: If it returns, the remote controller or its board needs replacing by a technician.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric E0: Remote controller transmission error

🧭 Check a few things first

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Shown on the remote controller (no fixed flash count in the table)

The remote controller reports a transmission error. The manual lists E0 and E3 together.

When to call a pro: If it returns, a technician needs to check the remote controller wiring.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric UP: Compressor overcurrent interruption

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 2 flashes

The outdoor side reports a compressor overcurrent interruption.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U3: Outdoor unit thermistor open or short

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 3 flashes

The outdoor side reports an open or short in the outdoor unit thermistors. The manual lists U3 and U4 together.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric UF: Compressor overcurrent (compressor locked)

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 4 flashes

The outdoor side reports compressor overcurrent interruption when the compressor is locked.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U5: Abnormal heat sink temperature

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 7 flashes

The outdoor side reports an abnormal temperature of the heat sink.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U8: Outdoor unit fan protection stop

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 8 flashes

The outdoor side reports an outdoor unit fan protection stop.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U6: Compressor overcurrent or power module abnormal

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 9 flashes

The outdoor side reports compressor overcurrent interruption or an abnormal power module.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U7: Superheat abnormality (low discharge temperature)

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 10 flashes

The outdoor side reports an abnormality of superheat due to low discharge temperature.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Mitsubishi Electric U9: Overvoltage, voltage shortage or current sensor error

πŸ›‘ Turn it off and call a licensed pro

Applies to: PLA-RP35/50/60/71/100/125/140BA ceiling cassette indoor units (Mr. Slim, OCH416 service manual). Shows as: Second self-check pattern, 11 flashes

The outdoor side reports an abnormality such as overvoltage or voltage shortage, an abnormal synchronous signal to the main circuit, or a current sensor error. The manual lists U9 and UH together.

When to call a pro: Have a licensed HVAC technician diagnose and repair it. The service manual treats this as a service repair.

Source: Mitsubishi Electric PLA-RP BA Service Manual OCH416 Rev. D, p.22

Safe first steps for any code

  1. Write down the exact code and how it shows (remote display or number of lamp blinks). Similar codes mean different things on different series.
  2. Turn the system off at the remote, switch off the breaker or disconnect for the unit, wait a few minutes, then turn it back on.
  3. Clean or replace the indoor unit air filters, and make sure nothing blocks the indoor or outdoor unit.
  4. Check that the condensate drain line is not blocked or kinked where you can see it.
  5. Replace the remote controller batteries if the display is dim or the unit does not respond.

πŸ›‘ Stop and call a licensed pro if

  • Any code pointing to refrigerant, the compressor, high pressure or the outdoor unit board. Refrigerant work legally needs a certified technician.
  • Burning smell, sparks, or a breaker that trips again after a reset.
  • Water leaking from the indoor unit that does not stop after the drain is clear.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician