Daikin U2 Error Code: Low-voltage or over-voltage detection

Updated October 2026 · Sourced from Daikin documentation

🧭 Check a few things first

The indoor unit found no power supply zero-cross detection for about 10 seconds, or the outdoor unit detected an abnormal voltage drop or rise. The compressor stops and restarts automatically after a 3-minute standby.

Is it safe to keep running? Check the steps below first. If it repeats, a licensed technician or electrician should check the supply voltage and the unit board.

U2 at a glance

Code / how it showsMeaningApplies to
U2
Shown on the remote controller (and as blinking lamps on the indoor unit)
Low-voltage or over-voltage detectionDaikin FTXS-L / FDXS-L inverter pair ductless series (09 to 36 class, models FTXS09-36LVJU, FDXS09-12LVJU)

Check this first

Only steps a homeowner can do safely. Do not open electrical panels or the burner area.

  1. Switch the unit off at the breaker, wait a minute, then switch it back on and see whether the code returns.
  2. If other appliances on the same circuit act up, mention that to the electrician or technician.

🛑 Stop and call a licensed pro if

  • If it repeats, a licensed technician or electrician should check the supply voltage and the unit board.
  • Any code pointing to refrigerant, the compressor, high pressure or the outdoor unit board. Refrigerant work legally needs a certified technician.
  • Burning smell, sparks, or a breaker that trips again after a reset.
  • Water leaking from the indoor unit that does not stop after the drain is clear.

Safe first steps for any Daikin code

  1. Write down the exact code and how it shows (remote display or number of lamp blinks). Similar codes mean different things on different series.
  2. Turn the system off at the remote, switch off the breaker or disconnect for the unit, wait a few minutes, then turn it back on.
  3. Clean or replace the indoor unit air filters, and make sure nothing blocks the indoor or outdoor unit.
  4. Check that the condensate drain line is not blocked or kinked where you can see it.
  5. Replace the remote controller batteries if the display is dim or the unit does not respond.

Source: Daikin Service Manual SiUS091133 - FTXS-L / FDXS-L Series, Troubleshooting p.107. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start · $1 for the full consultation · Money-back guarantee

Shaun Cain · Certified HVAC & Refrigeration Technician · Ask an HVAC technician

Related Daikin codes

A1 : Indoor unit PCB abnormalityA5 : Freeze-up or heating peak-cut protectionA6 : Indoor fan motor abnormalityC4 : Indoor heat exchanger thermistor abnormalityC9 : Room temperature thermistor abnormalityU0 : Refrigerant shortageU4 : Signal error between indoor and outdoor unitUA : Unspecified voltage between indoor and outdoor unitE1 : Outdoor unit PCB abnormalityE5 : Compressor overload (OL) activationE6 : Compressor lockE7 : Outdoor DC fan lock

All 26 Daikin codes and series →

← All HVAC and water heater codesAsk an HVAC technician