Daikin U0 Error Code: Refrigerant shortage

Updated October 2026 · Sourced from Daikin documentation

🛑 Turn it off and call a licensed pro

The system detects a refrigerant shortage by checking the input current and compressor running frequency, the discharge pipe temperature and expansion valve opening, or the suction and discharge temperature difference.

Is it safe to keep running? No. Turn it off and get it checked. Refrigerant work must be done by a licensed technician. Do not try to add or handle refrigerant yourself.

U0 at a glance

Code / how it showsMeaningApplies to
U0
Shown on the remote controller (and as blinking lamps on the indoor unit)
Refrigerant shortageDaikin FTXS-L / FDXS-L inverter pair ductless series (09 to 36 class, models FTXS09-36LVJU, FDXS09-12LVJU)

Check this first

Only steps a homeowner can do safely. Do not open electrical panels or the burner area.

  1. Turn the system off until it is serviced.

🛑 Stop and call a licensed pro if

  • Refrigerant work must be done by a licensed technician. Do not try to add or handle refrigerant yourself.
  • Any code pointing to refrigerant, the compressor, high pressure or the outdoor unit board. Refrigerant work legally needs a certified technician.
  • Burning smell, sparks, or a breaker that trips again after a reset.
  • Water leaking from the indoor unit that does not stop after the drain is clear.

Safe first steps for any Daikin code

  1. Write down the exact code and how it shows (remote display or number of lamp blinks). Similar codes mean different things on different series.
  2. Turn the system off at the remote, switch off the breaker or disconnect for the unit, wait a few minutes, then turn it back on.
  3. Clean or replace the indoor unit air filters, and make sure nothing blocks the indoor or outdoor unit.
  4. Check that the condensate drain line is not blocked or kinked where you can see it.
  5. Replace the remote controller batteries if the display is dim or the unit does not respond.

Source: Daikin Service Manual SiUS091133 - FTXS-L / FDXS-L Series, Troubleshooting p.104. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start · $1 for the full consultation · Money-back guarantee

Shaun Cain · Certified HVAC & Refrigeration Technician · Ask an HVAC technician

Related Daikin codes

A1 : Indoor unit PCB abnormalityA5 : Freeze-up or heating peak-cut protectionA6 : Indoor fan motor abnormalityC4 : Indoor heat exchanger thermistor abnormalityC9 : Room temperature thermistor abnormalityU2 : Low-voltage or over-voltage detectionU4 : Signal error between indoor and outdoor unitUA : Unspecified voltage between indoor and outdoor unitE1 : Outdoor unit PCB abnormalityE5 : Compressor overload (OL) activationE6 : Compressor lockE7 : Outdoor DC fan lock

All 26 Daikin codes and series →

← All HVAC and water heater codesAsk an HVAC technician