Home/HVAC & Water Heater Codes/Lennox/E311

Lennox E311 Error Code: Restricted airflow, heat rate reduced

Updated October 2026 Β· Sourced from Lennox documentation

🧭 Check a few things first

The control reports restricted airflow in heating and reduces the firing rate to match the available cfm.

Is it safe to keep running? Check the steps below first. Call a licensed HVAC technician if the code continues after a clean filter and open vents. The ductwork may need work.

E311 at a glance

Code / how it showsMeaningApplies to
E311
Shown as an E code on the 7-segment display of the integrated control
Restricted airflow, heat rate reducedLennox SL280UHVK two-stage variable-speed furnace (integrated control, 7-segment display)

Check this first

Only steps a homeowner can do safely. Do not open electrical panels or the burner area.

  1. Replace a dirty air filter, then restore power and see if the code returns.
  2. Make sure supply and return vents are open and not blocked by furniture or rugs.

πŸ›‘ Stop and call a licensed pro if

  • Call a licensed HVAC technician if the code continues after a clean filter and open vents. The ductwork may need work.
  • You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
  • Flame rollout, limit or pressure switch codes that come back after one reset.
  • Anything involving the control board, gas valve, flame sensor, igniter or venting.
  • A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.

Safe first steps for any Lennox code

  1. Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
  2. Replace or clean the furnace air filter.
  3. Check the thermostat: correct mode, set above room temperature, and fresh batteries.
  4. Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
  5. Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
  6. On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).

Source: Lennox SL280UHVK Installation Instructions 508553-01 (01/2025), Ignition Control Diagnostic Codes (continued), p.37. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician

Related Lennox codes

E110 : AC line voltage lowE111 : Line voltage polarity reversedE112 : Earth ground not detectedE113 : AC line voltage highE115 : Low 24V control voltageE200 : Rollout open (hard lockout)E204 : Gas valve relay problemE206 : Gas valve second-stage relay problemE223 : Low pressure switch failed to closeE224 : Low pressure switch failed to openE225 : High pressure switch failed to closeE226 : High pressure switch failed to open

All 31 Lennox codes and series β†’

← All HVAC and water heater codesAsk an HVAC technician