Home/HVAC & Water Heater Codes/Lennox/E207

Lennox E207 Error Code: Hot surface igniter open

Updated October 2026 Β· Sourced from Lennox documentation

πŸ›‘ Turn it off and call a licensed pro

The hot surface igniter (HSI) is sensed as open, so the burners cannot be lit. It is listed as a 60 minute soft lockout fault.

Is it safe to keep running? No. Turn it off and get it checked. Call a licensed HVAC technician. The igniter is fragile and must be tested and replaced by a professional.

E207 at a glance

Code / how it showsMeaningApplies to
E207
Shown as an E code on the 7-segment display of the integrated control
Hot surface igniter openLennox SL280UHVK two-stage variable-speed furnace (integrated control, 7-segment display)

Check this first

Only steps a homeowner can do safely. Do not open electrical panels or the burner area.

  1. Turn the furnace power switch or breaker off for 30 seconds, then back on, and see if the code clears.
  2. Check the thermostat is set to Heat, set above room temperature, and has fresh batteries if it uses them.

πŸ›‘ Stop and call a licensed pro if

  • Call a licensed HVAC technician. The igniter is fragile and must be tested and replaced by a professional.
  • You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
  • Flame rollout, limit or pressure switch codes that come back after one reset.
  • Anything involving the control board, gas valve, flame sensor, igniter or venting.
  • A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.

Safe first steps for any Lennox code

  1. Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
  2. Replace or clean the furnace air filter.
  3. Check the thermostat: correct mode, set above room temperature, and fresh batteries.
  4. Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
  5. Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
  6. On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).

Source: Lennox SL280UHVK Installation Instructions 508553-01 (01/2025), Ignition Control Diagnostic Codes (continued), p.37. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician

Related Lennox codes

E110 : AC line voltage lowE111 : Line voltage polarity reversedE112 : Earth ground not detectedE113 : AC line voltage highE115 : Low 24V control voltageE200 : Rollout open (hard lockout)E204 : Gas valve relay problemE206 : Gas valve second-stage relay problemE223 : Low pressure switch failed to closeE224 : Low pressure switch failed to openE225 : High pressure switch failed to closeE226 : High pressure switch failed to open