Carrier and Bryant 14 Error Code: Ignition lockout
Updated October 2026 Β· Sourced from Carrier and Bryant documentation
Carrier and Bryant 14 means different things on different series:
- Carrier 59SC5A single-stage 4-way multipoise condensing gas furnace (Series 1 and 2): The furnace failed to light and the control locked out. It resets itself after three hours. The label points to status code 34 for causes.
- Bryant 926TC two-stage variable-speed ECM multipoise condensing gas furnace: The furnace locked out after failing to light or keep flame. Minor codes cover 4 consecutive ignition tries (14.1), flame lost 3 times after 70s of heating (14.2), 7 loss of flame events during a heat request (14.3) and 7 LPS open events during a heat request (14.4).
Is it safe to keep running? Check the steps below first. If the lockout repeats, call a licensed technician. The label lists the hot surface igniter, flame sensor, gas valve and gas pressure as things to check.
14 at a glance
| Code / how it shows | Meaning | Applies to |
|---|---|---|
| 14 Status LED flashes: first digit is short flashes, second digit is long flashes | Ignition lockout | Carrier 59SC5A single-stage 4-way multipoise condensing gas furnace (Series 1 and 2) |
| 14 Also: 14.1, 14.2, 14.3, 14.4 Status LED flashes: first digit is short flashes, second digit is long flashes; display shows 14.1 to 14.4 | Ignition lockout | Bryant 926TC two-stage variable-speed ECM multipoise condensing gas furnace |
Check this first
Only steps a homeowner can do safely. Do not open electrical panels or the burner area.
- Check the thermostat is set to Heat, set above room temperature, and has fresh batteries if it uses them.
- Make sure the manual gas shutoff valve is open, following the lighting instructions on the furnace label.
- Turn the furnace power off at the switch or breaker, wait one minute, then turn it back on to see whether the code returns.
- Look outside at the furnace vent and intake pipe ends. Make sure snow, leaves or a nest are not blocking them. Look only, do not touch the pipes.
- Look at the condensate drain line and trap (if you can see it without removing any panel) for a clog, kink or standing water.
π Stop and call a licensed pro if
- If the lockout repeats, call a licensed technician. The label lists the hot surface igniter, flame sensor, gas valve and gas pressure as things to check.
- If the lockout repeats, call a licensed technician. Flame sensor, igniter, gas pressure and venting checks are service work.
- You smell gas. Leave the house, do not touch switches, and call your gas utility from outside.
- Flame rollout, limit or pressure switch codes that come back after one reset.
- Anything involving the control board, gas valve, flame sensor, igniter or venting.
- A carbon monoxide alarm sounds. Get everyone outside and call 911 or the fire department.
Safe first steps for any Carrier and Bryant code
- Count the LED flashes through the blower door window before you switch anything off. Cutting power can clear the code.
- Replace or clean the furnace air filter.
- Check the thermostat: correct mode, set above room temperature, and fresh batteries.
- Make sure the furnace power switch and breaker are on. If the furnace has locked out, turning the power off and back on once restarts it.
- Make sure the gas valve is in the ON position, following the lighting instructions on the furnace label only.
- On high-efficiency furnaces, look at the outside vent and intake pipes for snow, ice, leaves or nests (look only, do not take pipes apart).
Sources: Carrier 59SC5A Installation, Start-up, Operating and Service and Maintenance Instructions, Fig. 62 Service Label, p.67; Bryant 926TC Installation, Start-up, Operating and Service and Maintenance Instructions, Service Label (Status Code Table), p.56. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.