LG CH10 Error Code: Indoor fan locked up

Updated October 2026 Β· Sourced from LG documentation

🧭 Check a few things first

The indoor unit fan has locked up (fan motor operation failure).

Is it safe to keep running? Check the steps below first. If the fan still does not run, a service technician should check the fan motor.

CH10 at a glance

Code / how it showsMeaningApplies to
CH10
Also: 10
On North American units, shown as blinking indicator LEDs (indoor unit, LED2 1 blink); on other markets shown as the number 10
Indoor fan locked upLG single-split and multi-split air conditioners (North America LED blink code chart)

Check this first

Only steps a homeowner can do safely. Do not open electrical panels or the burner area.

  1. Turn the power off and look at the indoor unit for anything blocking the air outlet or fan.
  2. Turn the power off or trip the circuit breaker for the unit, wait about 5 minutes, then turn it back on.

πŸ›‘ Stop and call a licensed pro if

  • If the fan still does not run, a service technician should check the fan motor.
  • Any code pointing to refrigerant, the compressor, high pressure or the outdoor unit board. Refrigerant work legally needs a certified technician.
  • Burning smell, sparks, or a breaker that trips again after a reset.
  • Water leaking from the indoor unit that does not stop after the drain is clear.

Safe first steps for any LG code

  1. Write down the exact code and how it shows (remote display or number of lamp blinks). Similar codes mean different things on different series.
  2. Turn the system off at the remote, switch off the breaker or disconnect for the unit, wait a few minutes, then turn it back on.
  3. Clean or replace the indoor unit air filters, and make sure nothing blocks the indoor or outdoor unit.
  4. Check that the condensate drain line is not blocked or kinked where you can see it.
  5. Replace the remote controller batteries if the display is dim or the unit does not respond.

Source: LG Single / Multi-Split Air Conditioner Error Codes (LG Canada help library), Error Code Chart. Codes are series-specific, so your unit's own manual is the final word. Reviewed October 2026.

Tell us the brand, model and code, and what you have already tried. Describing it is free, and a chat with a verified HVAC technician costs $1.

Free to start Β· $1 for the full consultation Β· Money-back guarantee

Shaun Cain Β· Certified HVAC & Refrigeration Technician Β· Ask an HVAC technician

Related LG codes

CH01 : Indoor return air thermistor faultCH02 : Indoor inlet pipe thermistor faultCH05 : Indoor to outdoor communication failureCH06 : Indoor outlet pipe thermistor faultCH09 : Indoor unit EEPROM errorCH12 : Indoor middle pipe thermistor faultCH21 : DC peak error or IPM faultCH22 : Current transformer 2 errorCH23 : DC link voltage too lowCH25 : Supply voltage too low or too highCH26 : Inverter compressor seized or not rotatingCH27 : Inverter section overcurrent (PSC fault)